Radiant Diesel Engine Gen-Set

What Radiant Series Diesel Generators?

The FMT Group radiant segment generator was created to fulfill the needs of middle range business needed. Radiant segment generators are available in three phase specification. Our engineers and the projection department created this product to fulfill the special needs of all the clients. Doosan Engine find the perfect match Marelli Alternator with the research team of Fmt Group innovation department. Our professional engineer team decide the produce Doosan Diesel Generator Engine with Marelli Alternators.

 

Radiant Series Diesel Generators Body Design

he Radiant segment generators have FMT power Doosan Engine and Marelli alternators. Our experienced team of engineers created this product with industrial energy power and brought it to you in the prestige concept (the prestige segment has industrial engine that works with 1500 rpm). This product was designed with a special cabin that is soundproof and that has finally solved you problem of space.

 

DOOSAN ENGINES

The power ratings of Emergency Standby and Prime are in accordance with ISO 8528.
Fuel Stop power in accordance with ISO 3046.
Electric power (kWe) must be considered cooling fan loss, alternator efficiency, altitude derating and ambient temperature. STANDBY POWER RATING is applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. A standby rated engine should be sized for a maximum of an 80% average load factor and 200 hours of operation per year. This includes less than 25 hours per year at the Standby Power rating. PRIME POWER RATING is available for an unlimited number of hours per year in variable load application. Variable load should not exceed a 70% average of the Prime Power rating during any operating period of 24 hours. The Total operating time at 100% Prime Power shall not exceed 500 hours per year. A 10% overload capability is available for a period of 1 hour withing a 12 hour period of operation. Total operating time at the 10% overload power shall not exceed 25 hours per year.

wm_112036895057

 

perkins_diesel_engine doosan_engine_marelli_alternator

 

DOOSAN ENGINES

The Doosan engine family continues to set new standards in the compact engine market. Developed alongside customers to fulfill their needs in the generator set, compressor, agricultural and general industrial markets.

 

MARELLI ALTERNATORS

With over 100 years of manufacturing excellence and experience, Marelli Motori is recognised as a leading supplier to the Power Generation, Industrial, Petrochemical and Marine Industries sectors offering a complete range of Low, Medium and High Voltage Alternator for Generators. These quality products are backed up by an organisation of skilled people providing sales, service and technical support to the high standards demanded by our customers.

marelli-motori_alternator

 

marelli-motori_alternator synchronous-alternators-25063-3531707

 

egzoz_system_diesel_generator

Exhaust System of Prestige Diesel Generator

In our generators all the exhaust system and the gases coming form it are placed inside the cabin (the body of the generator). This special design makes it possible for the gases to come out easily and without noise. FMT Group made this special design to protect you and everyone that maintains the generator from getting hurt.

 

Radiant Series Diesel Generators AMF Control Panel

FMT 509 Control Panel
The controller is a comprehensive AMF unit for
single genset standby or dual genset mutual standby operations.
The unit is available with MPU or CANBUS versions. The CANBUS version connects to ECU controlled electronic engines providing engine control, protection and instrumentation without extra senders. The ECU alarms are displayed in text. The unit has an optional internal GSM modem module and is able to initiate modem calls and send SMS messages in fault conditions through either internal or external modems. The unit provides a comprehensive set of digitally adjustable timers, threshold levels, input and output configurations, operating sequences and engine types. All programs may be modified via front panel pushbuttons, and do not require an external unit.
Last 100 faults are stored in the event log file. The event log includes not only the date-time information, but also a comprehensive list of measured genset parameters at the time that the fault has occurred. The WINDOWS based RAINBOW program allows remote monitoring and control. The unit supports MODBUS protocol enabling communication with PLCs and building management systems. The MODBUS protocol is also supported through GSM and PSTN modems. The unit offers multiple language support.

control_panel_fmt

 

fmt_control_panel_generator_power fmt_control_panel_generator fmt_control_panel_diesel_generator fmt_control_panel

 

Data Sheets

FDD232M – 232 kva

FDD255M – 255 kva

FDD275M – 275 kva

FDD330M – 330 kva

FDD385M – 385 kva

FDD410M – 410 kva

FDD450M – 450 kva

FDD486M – 486 kva

FDD510M – 510 kva

FDD585M – 585 kva

FDD625M – 625 kva

FDD710M – 710 kva

FDD750M – 750 kva

FDD830M – 830kva

 